- Home
- About us
- R&D Areas
- R&D Management Areas
- R&D Facilities
- Bridge Engineering and Structures Division »
- Mobile Bridge Inspection Unit
- Schmidt Rebound Hammer
- Pundit PL-200 Ultrasonic Pulse Velocity Tester
- VW Load Cells
- Strain Measuring System (Vibrating wire method)
- Structural Testing System
- Pile Integrity Tester (PIT)
- Strain Measurement System - DAQ
- Fourier Transform Infrared Spectroscopy (FTIR)
- Universal Testing Machine 5kN (UTM)
- Universal Testing Machine 2000kN (UTM)
- FFT Analyser
- Geotechnical Engineering Division »
- Flexible Pavements Division »
- Pavement EvaluationDivision »
- Rigid Pavements Division »
- Traffic Engineering and Safety Divsion »
- Transport Planning Division »
- Bump Integrator
- Dipstick Road Profiler
- Dynamic Heavy Testing
- Expansion Joint Testing
- Noise, Vibration & Harshness
- Roughometer
- Walking Profiler
- Wheel Weigh Pads
- Bridge Engineering and Structures Division »
- Publications
- HRD
- Events
- News
- Rajbhasha
- Tenders
Fourier Transform Infrared Spectroscopy (FTIR)
Instrument Details
Make | : | Perkin Elmer, Singapore | ||||||||||
Model | : | Spectrum-2 | ||||||||||
Specification | : | |||||||||||
|
Working Principles
Fourier Transform Infrared Spectroscopy relies on the fact that the most molecules absorb light in the infra-red region of the electromagnetic spectrum. This absorption corresponds specifically to the bonds present in the molecule. The frequency range are measured as wave numbers typically over the range 4000 – 600 cm-1. It is a technique used to obtain an infrared spectrum of absorption or emission of a solid, liquid or gas. This simultaneously collects high-spectral-resolution data over a wide spectral range. This confers a significant advantage over a dispersive spectrometer, which measures intensity over a narrow range of wavelengths at a time.
Applications
Fourier Transform infrared spectroscopy (FTIR spectroscopy) covers a wide range of chemical applications, especially for polymers and organic compounds for examples paints, adhesives, resins, polymers, coatings and drugs. It is a technique used to obtain an infrared spectrum of absorption or emission of a solid, liquid or gas. An FTIR spectrometer simultaneously collects high-spectral-resolution data over a wide spectral range.
User Instructions
- Keep the instrument dry. Avoid spilling liquid onto the instrument. Clean all external spills immediately.
- Do not use a flammable gas to purge the instrument. The instrument contains a hot source, and a fire or explosion will result.
- Only plug the instrument power supply into a socket power outlet that is provided with a protective earth connection.
Contact Details
CSIR-Central Road Research Institute,
Delhi-Mathura Road, New Delhi-110025
Phone: 011-26832173, 26832325
Website: http://www.crridom.gov.in
Email: director.crri@nic.in
Instrument Usage Charges(Including GST)